How we solved a chemical plant's level problem

A chemical plant in Shandong used radar level meters for their reactor vessels. But the material had vapor. The radar often lost signal. This caused overflow. We suggested using weighing instead. We put one tank weighing load cell under each of the three legs. Accuracy C3, capacity 50 tons. After installation, the weight shown on the indicator matched the actual material added exactly. The client said: "Weighing is the most direct method. Vapor does not affect it." Sometimes the simplest way is the most reliable.
Full Technical Parameters (Table Format)
|
Parameter |
Value |
|
Capacity range |
500 kg to 100 tons |
|
Accuracy class |
C3 |
|
Error |
≤ ±0.1% |
|
Hygienic version material |
316L stainless steel |
|
Surface finish (hygienic) |
Electro-polished, Ra ≤0.4μm |
|
Elastic body design |
Blind hole, strain gauge fully sealed inside |
|
Protection class |
IP68 |
|
Bottom feature |
Anti-tilt bolt |
|
Top feature |
Self-aligning rocker column |

Kit form: buy and install
We provide a complete weighing module kit. It includes the tank weighing load cell, top and bottom plates, anti-tilt bolts, and horizontal tie rods. You do not need to design your own mounting parts. Just drill holes according to the drawing and fix them. Supports 3-point or 4-point configurations. We include a junction box to sum the signals. For tall silos, add limit rods to prevent wind from blowing them over. A common question: "Can your tank weighing load cell handle thermal expansion of a hot tank?" Yes, the rocker column self-aligns to keep accuracy. Yixing Silvanus Electric Manufacture Co., Ltd. has been making sensors since 2007. Choosing us means you can turn a normal tank into a smart scale in half a day without hiring a specialist.






Hot Tags: tank weighing load cell, China tank weighing load cell manufacturers, suppliers, factory